1.
Prim Health Care Res Dev ; 22: e56, 2021 10 18.
Article in English | MEDLINE | ID: covidwho-1475228

ABSTRACT

AIM: To validate the Roth score as a triage tool for detecting hypoxaemia. BACKGROUNDS: The virtual assessment of patients has become increasingly important during the corona virus disease (COVID-19) pandemic, but has limitations as to the evaluation of deteriorating respiratory function. This study presents data on the validity of the Roth score as a triage tool for detecting hypoxaemia remotely in potential COVID-19 patients in general practice. METHODS: This cross-sectional validation study was conducted in Dutch general practice. Patients aged ≥18 with suspected or confirmed COVID-19 were asked to rapidly count from 1 to 30 in a single breath. The Roth score involves the highest number counted during exhalation (counting number) and the time taken to reach the maximal count (counting time).Outcome measures were (1) the correlation between both Roth score measurements and simultaneous pulse oximetry (SpO2) on room air and (2) discrimination (c-statistic), sensitivity, specificity and predictive values of the Roth score for detecting hypoxaemia (SpO2 < 95%). FINDINGS: A total of 33 physicians enrolled 105 patients (52.4% female, mean age of 52.6 ± 20.4 years). A positive correlation was found between counting number and SpO2 (rs = 0.44, P < 0.001), whereas only a weak correlation was found between counting time and SpO2 (rs = 0.15, P = 0.14). Discrimination for hypoxaemia was higher for counting number [c-statistic 0.91 (95% CI: 0.85-0.96)] than for counting time [c-statistic 0.77 (95% CI: 0.62-0.93)]. Optimal diagnostic performance was found at a counting number of 20, with a sensitivity of 93.3% (95% CI: 68.1-99.8) and a specificity of 77.8% (95% CI: 67.8-85.9). A counting time of 7 s showed the best sensitivity of 85.7% (95% CI: 57.2-98.2) and specificity of 81.1% (95% CI: 71.5-88.6). CONCLUSIONS: A Roth score, with an optimal counting number cut-off value of 20, maybe of added value for signalling hypoxaemia in general practice. Further external validation is warranted before recommending integration in telephone triage.


Subject(s)
COVID-19 , Triage , Adult , Aged , Cross-Sectional Studies , Family Practice , Female , Humans , Hypoxia/diagnosis , Male , Middle Aged , SARS-CoV-2
2.
BMJ Open Respir Res ; 8(1)2021 09.
Article in English | MEDLINE | ID: covidwho-1394125

ABSTRACT

OBJECTIVES: To evaluate the performance of direct-to-consumer pulse oximeters under clinical conditions, with arterial blood gas measurement (SaO2) as reference standard. DESIGN: Cross-sectional, validation study. SETTING: Intensive care. PARTICIPANTS: Adult patients requiring SaO2-monitoring. INTERVENTIONS: The studied oximeters are top-selling in Europe/USA (AFAC FS10D, AGPTEK FS10C, ANAPULSE ANP 100, Cocobear, Contec CMS50D1, HYLOGY MD-H37, Mommed YM101, PRCMISEMED F4PRO, PULOX PO-200 and Zacurate Pro Series 500 DL). Directly after collection of a SaO2 blood sample, we obtained pulse oximeter readings (SpO2). SpO2-readings were performed in rotating order, blinded for SaO2 and completed <10 min after blood sample collection. OUTCOME MEASURES: Bias (SpO2-SaO2) mean, root mean square difference (ARMS), mean absolute error (MAE) and accuracy in identifying hypoxaemia (SaO2 ≤90%). As a clinical index test, we included a hospital-grade SpO2-monitor (Philips). RESULTS: In 35 consecutive patients, we obtained 2258 SpO2-readings and 234 SaO2-samples. Mean bias ranged from -0.6 to -4.8. None of the pulse oximeters met ARMS ≤3%, the requirement set by International Organisation for Standardisation (ISO)-standards and required for Food and Drug Administration (FDA) 501(k)-clearance. The MAE ranged from 2.3 to 5.1, and five out of ten pulse oximeters met the requirement of ≤3%. For hypoxaemia, negative predictive values were 98%-99%. Positive predictive values ranged from 11% to 30%. Highest accuracy (95% CI) was found for Contec CMS50D1; 91% (86-94) and Zacurate Pro Series 500 DL; 90% (85-94). The hospital-grade SpO2-monitor had an ARMS of 3.0% and MAE of 1.9, and an accuracy of 95% (91%-97%). CONCLUSION: Top-selling, direct-to-consumer pulse oximeters can accurately rule out hypoxaemia, but do not meet ISO-standards required for FDA-clearance.


Subject(s)
Blood Gas Analysis/instrumentation , Oximetry , Oxygen , Aged , Critical Care , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Oximetry/instrumentation